​Medica EasyStat Technical Specifications

Sample Type:  Whole blood

Sample Size:  120 uL Syringe mode/95 uL Capillary mode

 

Measured Parameters and Limits

​

PO2 : 5–700 mmHg

PCO2 :  5.0–150.0 mmHg

pH : 6.500–8.000 pH units

Hct : 10–70%

Na+ : 80–200 mmol/L

K+ : 1.0–20.0 mmol/L

Ca++ : 0.25–5.00 mmol/L

 

Calculated Parameters

​

THb (Total Hemoglobin) : 3.3–23.3 g/dL

pH (T) :  pH temperature corrected

PCO2 (T) :  PCO2 temperature corrected

PO2 (T) :  PO2 temperature corrected

TCO2 (Total Carbon dioxide)  : 0–50 mmol/L

HCO3 (Bicarbonate) :  0–50 mmol/L

BEb (Base Excess in blood) :  -25.0 to 25.0 mmol/L

BEecf (Base Excess in extracellular fluid) :  -25.0 to 25.0 mmol/L

SBC (Standard Bicarbonate) :  0–50 mmol/L

%SO2c (Oxygen Saturation) :  40.0–100.0% (calculated at normal P50)

CtO2 (Oxygen Content)  : 3.0–30.0 mL/dL

A-aDO2 (Alveolar arterial oxygen gradient) :  0–700 mmHg

RI (Respiratory Index) :  0.0–70.0

Ca++ (7.4) (for 7.2<pH<=7.6)  :  0.22–5.58 mmol/L

 

Input Parameters

​

Patient Temperature :  (20–45°C)  Time Drawn   (00:00)

Hemoglobin  :  (3.0–30.0 g/dL) Sample Source (arterial, mixed venous, venous)

FIO2 (Fraction Inspired Oxygen) :  (10–100%)

Sample Type : (radial, brachial, femoral, arterial line)

Sample Source : (arterial, mixed venous, venous)

Time Drawn : (00:00)

Patient ID  : (14 digits)

Operator ID : (14 digits)

 

Sample Temperature Control:  37.0°C ± 0.2°C

 

Ambient Conditions: 15–30°C (59-86°F), 500–800 mmHg (max 15 PSI)

5–85% relative humidity, non-condensing atmospheric air environment (21% O2)

 

Analysis Time:  <120 seconds

 

Data Storage:  64 Patient results with Operator ID, Patient ID, Date and Time

QC—up to 93 results for each Level (Blood Gas/Electrolytes 1, 2, 3, Hct 1, 2)

 

Calibration: Automatic or On-Demand

 

Input/Output:  Numeric keypad, graphic display, 27 column thermal line printer, barcode reader port, RS-232 computer interface port

 

Power: 100/115~VAC, 50–60 Hz, 0.8 A or 220~VAC, 50–60 Hz, 0.4 A

Refer to the chassis serial number label for the voltage that has been factory set on your analyzer, and for proper fuse replacement.

 

Size & Weight: 14.5" W x 12.5" H x 7.0" D (37cm W x 32cm H x 18cm D), 17lbs (7.7 kg) with Reagent Module